We appreciate your interest in the NSN part 500471-1 under 5950-01-318-6661. If you are looking to receive a quick and personalized quote, please fill out our Instant RFQ with as much information as possible so that we can best create a solution to fit your needs. National Stock Numbers are 13-digit serial numbers assigned to specific items in the federal supply chain. These numbers are not arbitrary and follow a particular classification system.
500471-1 is manufactured by General Dynamics Ots Inc with CAGE Code 21562 and is described as Transformer Assembl. Like any other part on our website, this item is available for purchase at any time. Furthermore, if you are interested in acquiring items that we do not currently list in our database, we invite you to complete an Instant RFQ with available information, and our team will review it and respond in 15 minutes or less.
Internet of Hardware is a leading distributor of NSN part 500471-1, and we can help you acquire both popular and hard-to-find aerospace and electronic components. Rest assured that our parts are only sourced from trusted global manufacturers such as General Dynamics Ots Inc when purchasing through us. Internet of Hardware is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited and certified enterprise, and we take significant measures to ensure all components are certified, quality-tested, and approved.
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.390 INCHES MINIMUM AND 2.430 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.730 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.410 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.450 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.068 INCHES MINIMUM AND 5.088 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 195.5 VOLT-AMPERE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
AEHZ | MAXIMUM OPERATING TEMP | 104.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.7 AMPERES AC NOMINAL ALL COMPONENTS SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 640.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 75.0 MILLIAMPERES AC MINIMUM 1ST COMPONENT 2ND SECONDARY AND 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 ALL COMPONENTS SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.7932 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 4.300 2ND COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 52.200 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 7.800 1ST COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 19.44 VOLTS-AMPERES 1ST COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 195.5 VOLTS-AMPERES ALL COMPONENTS SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 45.824 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.70 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 56.90 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 71.60 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 24.30 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.60 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.20 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
ABMK | OVERALL WIDTH | 2.117 INCHES MINIMUM AND 2.217 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.115 INCHES MINIMUM SINGLE GROUP AND 0.135 INCHES MAXIMUM SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 2 SECONDARY 1ST COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.0886 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.540 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 2.4 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 44.96 VOLTS-AMPERES 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL ALL COMPONENTS SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 30 TURRET |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 2.56 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 2.62 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 159.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 33.85 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 38.30 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 41.50 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 70.90 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 74.10 AC VOLTS NOMIN |
TEST | TEST DATA DOCUMENT | 16340-11-00151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |