We appreciate your interest in the NSN part 49336 under 5950-00-385-8906. If you are looking to receive a quick and personalized quote, please fill out our Instant RFQ with as much information as possible so that we can best create a solution to fit your needs. National Stock Numbers are 13-digit serial numbers assigned to specific items in the federal supply chain. These numbers are not arbitrary and follow a particular classification system.
49336 is manufactured by Astec America Inc with CAGE Code 08742 and is described as Transformer Power. Like any other part on our website, this item is available for purchase at any time. Furthermore, if you are interested in acquiring items that we do not currently list in our database, we invite you to complete an Instant RFQ with available information, and our team will review it and respond in 15 minutes or less.
Internet of Hardware is a leading distributor of NSN part 49336, and we can help you acquire both popular and hard-to-find aerospace and electronic components. Rest assured that our parts are only sourced from trusted global manufacturers such as Astec America Inc when purchasing through us. Internet of Hardware is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited and certified enterprise, and we take significant measures to ensure all components are certified, quality-tested, and approved.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-385-8906 Item Description: Transformer Power | 5950 | 003858906 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
49336 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS8 ALL GROUPINGS8 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS0.250 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 0.6 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 8.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ALL VOLTAGES ARE STATED AS OPEN CIRCUIT; ALL CURRENTS ARE STATED AS RECTIFIED; 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARIES 5 & 6 ARE RATED 115VRMS |
THSD | THREAD SERIES DESIGNATOR | UNF ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 20 THREADED STUD |